BTM186B low pressure blasting test machine

Equipment overview

       BTM186B low pressure blasting test machine is used in the conventional blasting test of automobile water pipe, pure rubber hose, turbo tube, evaporator, condenser, radiator, filter and other low pressure specimens。The test pressure, pressure increase rate and other parameters can be set in the test program, and the machine can be fully automatic after setting。Test the maximum pressure value of the specimen under normal temperature conditions, and determine whether the quality of the specimen meets the requirements according to relevant standards。It involves many fields such as quality inspection institutions, auto parts, aerospace, engineering machinery, shipbuilding industry, colleges and universities, and research institutes。

 

Functional characteristics

1. The diversity of test waveforms can realize the direct pressure boost blasting, the pressure withstand blasting with one stage pressure boost and pressure maintain, and the pressure withstand blasting curve with two stage pressure boost and pressure maintain;

2, the pressure test process can be pre-set before the equipment operation, including the boost rate, pressure holding pressure, pressure holding time and other related parameters;

3. The structural design of the hydraulic control cabinet and test box adopts a unified style, and the overall appearance of the equipment is coordinated and beautiful;

4, the internal structure is reasonable, the layout is beautiful, the use of non-welded pipe connection, prevent leakage, and easy maintenance;

5. Written by Siemens PLC;The high quality hydraulic components and control components ensure the safety and stability of the equipment for a long time。


Technical index

Technical project

Parameter index

Equipment type

BTM186B series

Specimen type

Cooling water pipe, nylon pipe, rubber pipe, turbo pipe, etc

Test pressure

0.05 ~ 1.8MPa Arbitrary setting

Pressurization mode

Pneumatic fluid

Pressure measurement accuracy

±0.5%FS

Pressure control accuracy

±2%FS

Boost rate

0.Adjustable from 1 to 10 mpa /min

Test medium

清水

Medium temperature

Room temperature RT

Ambient temperature

Room temperature RT

Installation mode

Reserved joint

Number of specimens

1路